Fig. 2(a) --- A1 LAYOUT
 

 

VALUE

PURPOSE

R1

50Ω for most applications

A1 base current

C1

≥ 1 nF (value not critical)

bypass input noise from R1

R2

200Ω - 1KΩ (FS once)

sets gain of A1 & hence start of logging

C2

1– 4pF (FS once)

cancels effect of input capacitance

R3
C3
0.3-10K
1- 3 pF
FS (once)
if needed

used to remove small overshoots

C4

0 – 4pF (FS once)

A1 comp cap

R4

~ 150K (200K pot)

corrects negative output offset of A1

RLIN

~ 100 - 300K (FS once)

linear extension corrects for detector roll off

DT1
RT0
RT1

- 30K
~ 5K


FS (app notes)

tempco as shown will correct for A1 out going negative as T↑
See App Notes

RV1, RV2, CV1, CV2

(FS once)

recovery nets

NOTE: FS = Factory Select; (the correct component value must be ascertained for each replicated unit).
        FS (once) = the correct component value needs to be factory- selected only once for a given layout; subsequent units will use the same component value (assuming reasonable detector matching).
 