PL200 Data Sheet

Spec Brief:

Package Size 7mmx7mm, packaged, 2x2 mm die
Input Rail Voltages +/-5V to +/- 8V
Operating Temperature range -55C to 95C The PL200 is burned in under power at 125C
Current draws at +/-6V 28ma I+, 34ma I-
Dynamic range linear input >Over 90 dB
Max dynamic range with tunnel diode 50dB For a single channel. Multiple channels can be summed for extended range.
Max dynamic range with Schottky detector 65dB For a single channel. Multiple channels can be summed for extended range.
Log linearity Tunable to +/-0.2db
Temperature drift <0.5dB after adjustment Stable over extended temperature ranges (-55C to +95C)
Input voltage noise density 1.25nv/√Hz
Input current noise density <1pa/√Hz
Risetime (10% to 90%) 4ns With full dynamic range, faster with 2 log stages eliminated
Pulse to CW variation <0.2dB A change in pulse duration from 10 ns to 1 ms (at high duty-cycle) does not affect pulse height for DC coupled designs. For pseudo AC coupled designs 90%+ duty cycles are possible.
Fall time to 50mv output <50ns (with recovery nets)
Max output voltage VCC-2.1V
Output slope adjustable