PL200 Data Sheet
Spec Brief:
| Package Size | 7mmx7mm, packaged, 2x2 mm die | |
| Input Rail Voltages | +/-5V to +/- 8V | |
| Operating Temperature range | -55C to 95C | The PL200 is burned in under power at 125C |
| Current draws at +/-6V | 28ma I+, 34ma I- | |
| Dynamic range linear input | >Over 90 dB | |
| Max dynamic range with tunnel diode | 50dB | For a single channel. Multiple channels can be summed for extended range. |
| Max dynamic range with Schottky detector | 65dB | For a single channel. Multiple channels can be summed for extended range. |
| Log linearity | Tunable to +/-0.2db | |
| Temperature drift | <0.5dB after adjustment | Stable over extended temperature ranges (-55C to +95C) |
| Input voltage noise density | 1.25nv/√Hz | |
| Input current noise density | <1pa/√Hz | |
| Risetime (10% to 90%) | 4ns | With full dynamic range, faster with 2 log stages eliminated |
| Pulse to CW variation | <0.2dB | A change in pulse duration from 10 ns to 1 ms (at high duty-cycle) does not affect pulse height for DC coupled designs. For pseudo AC coupled designs 90%+ duty cycles are possible. |
| Fall time to 50mv output | <50ns (with recovery nets) | |
| Max output voltage | VCC-2.1V | |
| Output slope | adjustable |