L-17D Log Video Amplifier IC

  • ANADYNE's Fast Ultra Low Noise Preamp; Compatible with many different input topologies for maximum flexibility.

  • Two More Linear Amplifiers; Integrated amplifiers allow for very low propagation delay and high dynamic range.

  • Eleven Log and Linear Extension Stages; Many of the stages are tunable making very precise and custom non linear transfers possible.

  • Direct Summing Junction for Dual LVA Circuits; Two or more L-17D's can be used in combination for even more dynamic range.

  • Output Amplifier Stage; Our output amplifier can drive 50 ohm cables and now comes with a short circuit protection option.

  • Hermetically sealed and thoroughly screened for high reliability applications.

Spec Sheets

INTEGRATED DC-COUPLED LOG VIDEO AMPLIFIER L-17D#A, L-17D#B, L-2010

Package Size 10mmx10mm, packaged, 2x3 mm die
Input Rail Voltages +/-5V to +/- 7V
Operating Temperature range -55C to 95C The L-17D is burned in under power at 150C
Current draws at +/-6V 32ma, I-, I+
Dynamic range linear input >92dBv positive input, 80dBv negative input
Max dynamic range with tunnel diode 50dB
Max dynamic range with Schottky detector 65dB
Log linearity Tunable to +/-1/3db
Temperature drift <0.5dB after adjustment
Input voltage noise density 1.2nv/√Hz
Input current noise density <1pa/√Hz
Risetime (10% to 90%) 8ns With full dynamic range, faster with 2 log stages eliminated
Transit time (50% to50%) 8ns Variation in transit time over full dynamic range can be tuned to <2ns
Pulse to CW variation <.0.2dB A change in pulse duration from 10 ns to 1 ms (at high duty-cycle) does not affect pulse height for DC coupled designs. For pseudo AC coupled designs 90%+ duty cycles are possible.
Fall time to 50mv output <50ns (with recovery nets)
Max output voltage VCC-2.1V
Output drive capability 80ma
Output slope adjustable

Reference Materials



Pricing

Please contact info@anadyneinc.com for current pricing information.

Export Information

If you choose to export Anadyne products and technology, you are responsible for compliance with the relevant export regulations, including the Export Administration Regulations (EAR). The following information does not replace the EAR nor your responsibilities thereunder as an exporter. It is intended to assist you in the export of Anadyne products and technology from the United States and is not to be used for U.S. Customs purposes as it does not reflect origin-based, conditional Harmonized Tariff Schedule (HTS) numbers.

 

All Export Control Classification Numbers (ECCNs) and Harmonized Tariff Schedule (HTS) information provided here is subject to change. It is therefore your obligation as an exporter to verify such information and comply with the current applicable regulations.  Anadyne makes no representations as to the accuracy or reliability of such information and is therefore in no way responsible for any damages or penalties suffered by you as a result of using or relying upon such information.

 

L-17D packaged parts: EAR99                 

L2010 die: EAR99                                     

Terms and Conditions of Sale

Click here for Anadyne's Terms and Conditions of Sale.